• High Voltage Fuse Cutout Switch Disconnector Outdoor
  • High Voltage Fuse Cutout Switch Disconnector Outdoor
  • High Voltage Fuse Cutout Switch Disconnector Outdoor
  • High Voltage Fuse Cutout Switch Disconnector Outdoor
  • High Voltage Fuse Cutout Switch Disconnector Outdoor
  • High Voltage Fuse Cutout Switch Disconnector Outdoor

High Voltage Fuse Cutout Switch Disconnector Outdoor

Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: Vcb
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Zhejiang, China
to see all verified strength labels (24)
  • Overview
  • Product Parameters
  • Packaging
  • Showroom
  • Workshop
Overview

Basic Info.

Model NO.
ZW32-40.5
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000
Rated Voltage
36kv
Installation Method
Withdrawable
Rated Current
630A/1250A
Rated Frequency
50/60Hz
Material
Steel, Expoxy Resin
Transport Package
Wooden Case
Specification
pcs
Trademark
SHENGSU ELECTRIC CO., LTD
Origin
China

Product Description

  
ZW32-40.5 outdoor high-voltage alternating-current vacuum circuit breaker is a new outdoor
high-voltage alternating-current switchgear of our vacuum circuit breaker series. Its rated voltage is 40.5kV. It applies to
places with such voltage level, including overhead lines, industria and mining enterprises, power stations, substations, etc.
Under its normal operating conditions and specified technical parameters, it can the system protection requirements of the grid.
It is charaterized by automatic re-making, stble operation and long elecric life.

Standard:
1.IEC 62271-100 High-voltage switchgear and
controlgear
2.GB/T 11022 -2011 Common specifications for high-voltage switchgear and controlgear standards
3.GB 1984 High-voltage alternating-current circuit-breakers
4.GB311.1 Insulation co-ordination for high voltage transmission and distribution equipment

Ambient condition:
1. Altitude: ≤ 2000m
2. Ambient temperature: -40°C~+40°C
3. Relative humidity:≤95% (daily average)or≤90% (monthly average)
4. Ambient pllution: IV
5.Wind speed:≤34m/s (equivalent to a pressure of 700pa on a cylindrical surface) .

 
Product Parameters

High Voltage Fuse Cutout Switch Disconnector Outdoor

 

Packaging
High Voltage Fuse Cutout Switch Disconnector Outdoor
High Voltage Fuse Cutout Switch Disconnector Outdoor

 

Showroom

High Voltage Fuse Cutout Switch Disconnector Outdoor
Workshop

High Voltage Fuse Cutout Switch Disconnector OutdoorHigh Voltage Fuse Cutout Switch Disconnector Outdoor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
35
Year of Establishment
2014-06-03